fieldcommunicator

Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field

description:Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount...
BASIC INFO

Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount


The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART® 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
 
YTA610 features include:

· Dual-compartment field-mount housing

· Choice of HART® 7, or FOUNDATION™ Fieldbus ITK 6 Protocol

· Local Parameter Setting function (Indicator model)

· Basic diagnosis
 

Features of Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount
 

Communications

The YTA610 has 4 to 20 mA analogue output signal with HART® 7 digital protocol or full digital FOUNDATION™ Fieldbus protocol.
 

Dual sensor input

The YTA610 in capable of dual sensor input. With the processing capability of the transmitter, this dual input can be used to provide Failed Sensor Backup, Temperature Averaging, or Differential Temperature measurement.
 

Sensor Matching

The Yokogawa YTA610 uses the IEC60751 standard to define the relationship between resistance and temperature for RTD sensors. This relationship is referred to as a Standard Curve. Sensor manufacturers use this same standard, but, because of construction process, each sensor has a unique temperature / resistance relationship. This is referred to as the Real RTD Curve. (The Real RTD Curve falls within the tolerance band of IEC60751 standard) In the 1920's, Hugh Longbourne Callendar and M.S. Van Dusen developed a set of coefficients that would modify the Standard Curve to match the Real RTD Curve; thus, removing the error generated by the difference between the two curves. Yokogawa's YTA610 with the CM1 option can accept these coefficients to adjust the Standard Curve to match the Real RTD Curve of the sensor; eliminating this error improves the accuracy of the YTA610 / Sensor system.

 

Accuracy

The YTA610 enables advanced linearization of 21 types of industrial temperature sensors and input signals. The A/D accuracy of the representative Pt100 sensor is 0.14℃. Analog D/A accuracy of the output is 0.03%.The YTA610 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a 4 to 20 mA DC or Fieldbus signal for transmission.The YTA610 supports HART® and FOUNDATION fieldbusTM communication protocols.HART types are certified as complying with SIL 2 for safety requirement.

 

Characters of Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount
 

High reliability

Dual-compartment housing realizes high resistance capability to harsh environments.
 

Variety of sensor inputs

The type of sensor input is user-selectable from thermocouples (T/C), RTDs, ohms, or DC millivolts.
 

Digital communication

HART protocol revision is 7 and FOUNDATION fieldbusTM ITK vesion is 6.2.

The instrument confi guration can be changed by the user with using the Fieldmate or Handheld terminal. 
 

Local Parameter Setting

Parameter confi guration by the push button offers easy and quick setup for parameters.
 

Self-diagnostics function

Continuous self-diagnostics capability ensures longterm performance and lower cost of ownership.
 

Dual universal inputs

Dual input can accept two thermocouple, RTD,ohm or DC millivolt inputs. Differential or average temperature measurement is selectable. The sensor backup function for automatically switches-over from the primary to the backup upon sensor failure.

 

SPECIFICATIONS of Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount
 

 Accuracy

HART communication type:A/D accuracy/span + D/A accuracy

Fieldbus communication type:A/D accuracy

 Cold Junction Compensation Accuracy

± 0.5°C (± 0.9 °F) for T/C only

 Ambient Temperature Effect (per 10°C change)

±0.1% or ±(Temperature coeffi cient/span), whichever is greater. 

 Stability

RTD: ±0.1% of reading or ±0.1°C per 2 years,whichever is greater at 23±2°C.

T/C: ±0.1% of reading or ±0.1°C per year, whichever is greater at 23±2°C.

 5 Year Stability

RTD: ±0.25% of reading or ±0.25°C,whichever is greater at 23±2°C.

T/C: ±0.5% of reading or ±0.5°C,whichever is greater at 23±2°C.

 Vibration Effect

The YTA610 is tested to the following specifications with no effect on performance per IEC 60770-1

10 to 60 Hz 0.21 mm peak displacement

60 to 2000 Hz 3g

 Power Supply Effect

±0.005% of calibrated span per volt




Model and Suffix Codes of Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount 

Model Suffix Codes Description
YTA610 . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . Temperature Transmitter
Output signal -J . . . . . . . . . . . . . . .. .
-F . . . . . . . . . . . . . . . ..
4 to 20 mA DC with digital communication HART 7protocol
Digital communication (FOUNDATION Fieldbus protocol)
A . . . . . . . . . . . . . .. Always A
Sensor input 1 . . . . . . . . . . . .
2 . . . . . . . . . . .. 
Single
Double
Housing code A . . . . . . . . . .
C . . . . . . . . . ..
Aluminum
Stainless
Electrical connection 0 . . . . . . . .
2 . . . . . . . .
4 . . . . . . . .
G1/2 female
1/2 NPT female
M20 female
Integral indicator D . . . . .
N . . . . . 
Digital indicator with Local Operating Switch
None
Mounting bracket B . . .
D . . . .
J . . . .
K . . ..  
N. . . 
SUS304 stainless steel 2-inch horizontal pipemountin bracke *1
SUS304 stainless steel 2-inch vertical pipe mounting bracket
SUS316 stainless steel 2-inch horizontal pipemountin bracke *1
SUS316 stainless steel 2-inch vertical pipe mounting bracket
None
Option codes /o Optional specification
                     

Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount

Yokogawa YTA110 Temperature Transmitter
Yokogawa YTA310 Temperature Transmitter
Yokogawa YTA320 Temperature Transmitter
Yokogawa YTA610 Temperature Transmitter
Yokogawa YTA710 Temperature Transmitter
Yokogawa YTA50 Temperature Transmitter
Yokogawa YTA70 Temperature Transmitter
Yokogawa YTA70P Temperature Transmitter


Selection Guide of Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount
 

Model

Sensor

Mounting

Sensor Input

Transmitter Output

Safety Approval

YTA110A

Single Sensor

Remote , or integrated with sensor

Thermocouple, RTD, ohms or DC milivolts

4-20mA
Brain or Hart 5

SIL2

YTA310A

Single Sensor

Remote , or integrated with sensor

Thermocouple, RTD, ohms or DC milivolts

4-20mA
Brain or Hart 5

SIL2

YTA320A

Dual Sensor

Remote , or integrated with sensor

Thermocouple, RTD, ohms or DC milivolts

4-20mA
Brain or Hart 5
Foundation Fieldbus

SIL2

YTA70

Single Sensor

head mount

Thermocouple, RTD, ohms or DC milivolts

4-20mA
Hart 5 and Hart 7

N.A.

YTA50

Single Sensor

head mount

Thermocouple, RTD, ohms or DC milivolts

4-20mA DC

N.A.

YTA70P

Single Sensor

Rail Mount

Thermocouple, RTD, ohms or DC milivolts

4-20mA,Hart 7

N.A.

 

Yokogawa YTA610-JA1A2DB YTA610 Temperature Transmitter Field Mount
 
YOKOGAWA EJA110A
YOKOGAWA EJA120A
YOKOGAWA EJA130A
YOKOGAWA EJA210A
YOKOGAWA EJA220A
YOKOGAWA EJA310A
YOKOGAWA EJA430A
YOKOGAWA EJA438A
YOKOGAWA EJA440A
YOKOGAWA EJA530A
YOKOGAWA EJA118W
YOKOGAWA EJA118N
YOKOGAWA EJA118Y
YOKOGAWA EJA438W
YOKOGAWA EJA438N
YOKOGAWA EJA115
 
YOKOGAWA EJA110E
YOKOGAWA EJA115E
YOKOGAWA EJA118E
YOKOGAWA EJA120E
YOKOGAWA EJA130E
YOKOGAWA EJA210E
YOKOGAWA EJA310E
YOKOGAWA EJA430E
YOKOGAWA EJA438E
YOKOGAWA EJA440E
YOKOGAWA EJA510E
YOKOGAWA EJA530E
 
YOKOGAWA EJX110A
YOKOGAWA EJX120A
YOKOGAWA EJX130A
YOKOGAWA EJX210A
YOKOGAWA EJX430A
YOKOGAWA EJX438A
YOKOGAWA EJX530A
YOKOGAWA EJX910A

EJA118W
EJA118N
EJA118Y
EJA438W
EJA438N
EJA115
 
EJA110E
EJA115E
EJA118E
EJA120E
EJA130E
EJA210E
EJA310E
EJA430E
EJA438E
EJA440E
EJA510E
EJA530E
 
EJX110A
EJX120A
EJX130A
EJX210A
EJX430A
EJX438A
EJX530A
EJX910A
YTA610
VI701
VI702
VF701
VF702


We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply YOKOGAWA,WEIDMULLER, ABB, MOELLER, SCHNEIDER ElECTIC,FUJI,OMRON,HONEYWELL,SIEMENS,FLUKE,PEPPERL+FUCHS,HIMA,Endress+ Hauser etc.
 
Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
  
3. SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 
Packaging: 
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)


Previous:Yokogawa EJA110E-JHS3C-71CDD Differential Pressure Transmitt Next:Yokogawa ZR402G-M-E-E-A Zirconia Oxygen Analyzer Separate ty